BE THERECold Chain Equipment Request a quote

PU / PIR · Rock Wool · XPS

Cold Room Panels & Insulated Sandwich Panels

Be There supplies PU and PIR sandwich panels for walk-in coolers, freezer rooms and insulated buildings: 50–200 mm thick, 950 or 1150 mm wide, up to 12 m long, with cam-lock or tongue-and-groove joints and steel, stainless or aluminium facings.

Insulation Panels & Boards−40 to +60 °C
≤ 0.022W/(m·K)PU / PIR core conductivity
50–200mmpanel thickness
12mlongest single panel
B1fire rating, PIR core

Specifications

Typical models.

Cold room sandwich panels and insulation boards for cold stores, freezer rooms, clean rooms and HVAC ducting. Cut to length, with the facings, thickness and joint type your project needs. Values are typical; we configure voltage, size or capacity and confirm data on the quotation.

Insulation Panels & Boards: typical models and specifications
ProductThicknessCore densityThermal conductivity λFire ratingFacings / size
PU / PIR cold room sandwich panel50–200 mm40–42 kg/m³≤ 0.022 W/(m·K)B1 (PIR core)PPGI 0.4–0.6 mm, SS304, embossed Al · width 950 / 1150 mm · length to 12 m
Double-sided aluminium foil PIR board20–200 mm35–45 kg/m³0.020–0.024 W/(m·K)B1Embossed Al foil both sides · 1200 × 2400 / 3000 mm
Rock wool board30–150 mm80–200 kg/m³≤ 0.040 W/(m·K)A1 non-combustible1200 × 600 mm · plain or foil-faced
XPS extruded polystyrene board20–100 mm25–45 kg/m³≤ 0.030 W/(m·K)B1 / B21200 × 600 mm · 150–700 kPa compressive

≈ approximate, measured at standard test conditions.

Features

Built for daily commercial use.

Cam-lock joints

Eccentric hook locks pull panels tight for an airtight cold room; tongue-and-groove for walls and ceilings.

High closed-cell rate

Polyurethane foam above 90% closed cells keeps λ stable and resists moisture.

Food-safe facings

Pre-painted steel, stainless steel or embossed aluminium for food processing and pharma rooms.

Full room kits

Panels, doors, PVC profiles, sealant and refrigeration unit can be shipped together.

Applications

Where it works.

  • Cold storage and freezer rooms
  • Fruit & vegetable pre-cooling
  • Clean rooms and pharma stores
  • Pre-insulated HVAC air ducts
  • Roof, wall and floor insulation
  • Insulated truck bodies

FAQ

Questions buyers ask.

Something else? Ask us directly

Which panel thickness do I need?
As a guide: 75–100 mm for chillers (0 °C to +5 °C), 120–150 mm for freezers (−18 °C to −25 °C), 150–200 mm for blast freezing rooms (−35 °C and below).
PU or PIR?
PIR has better fire behaviour (B1) at a similar λ. PU is the economical choice where fire rules allow it.
Can you supply the whole cold room?
Yes. Send us inner dimensions and target temperature and we quote panels, door, refrigeration unit and accessories.
What are walk-in cooler panels made of?
A rigid polyurethane (PU) or polyisocyanurate (PIR) foam core bonded between two metal skins, usually pre-painted galvanised steel. Food and pharma rooms often use stainless steel or embossed aluminium on the inside.
Can I buy replacement panels for an existing walk-in?
Yes. Send the panel thickness, width, joint type and facing colour, or a photo of the panel edge, and we match it.

Buyer's guides

Before you order.

All guides

Buying guide11 min read

Insulated Metal Panels (IMP): Types, R-Values, Thickness and Price

How IMP panels are built, which profile and core suit your building or cold store, and what R-value, thickness and price to expect.

Read the guide

Buying guide11 min read

Metal Roof Panels and Insulated Roof Panels: Profiles, Spans, R-Values

Single-skin sheets or insulated sandwich roof panels? Compare profiles, spans, R-values, condensation risk and fire behaviour before you specify a roof.

Read the guide

Technical10 min read

SIP Panels vs Insulated Sandwich Panels: Structure, Cost and Uses

Both are foam-core panels, but one is wood-faced house framing and the other is a metal-skinned envelope for industrial buildings and cold stores.

Read the guide

Buying guide11 min read

Insulated Wall Panels: Exterior, Interior and Cold Store Wall Systems

How insulated wall panels compare with stud walls, precast and external insulation, what R-value your walls need, and which system suits a cold store.

Read the guide

Technical11 min read

Mineral Wool Insulation and Rock Wool Sandwich Panels: Fire and R-Value

What rock wool and stone wool are, how they compare with fiberglass and PIR, and where non-combustible rock wool sandwich panels belong in a cold store.

Read the guide

Technical10 min read

Insulation R-Value Chart: Foam Board, Fiberglass, Mineral Wool and Panels

R-value per inch for every common insulation type, the thickness you need for R-10, R-20 or R-30, and what each material typically costs.

Read the guide

Request a quote

Get a price for
insulation.

Phone / WhatsApp+86 159 3316 2577
OfficeUnit 000612, F21 Youth World, next to Oriental Plaza, No. 109 Fazhan Avenue, Dongcheng Experimental Zone, Yiling District, Yichang, Hubei, China

We answer within one working day with price, lead time and shipping options. See our privacy notice.